Abstract:A new anatomically accurate eye model with tear film in front of the cornea was proposed based on the eye model proposed by Hwey-Lan Liou.Due to incorporating tear film into the eye model,the model has five refractive surfaces,thus distinguishing it from previously published eye models that have four or fewer refractive surfaces.It has an equivalent power of 60.40 D,and an axial length of 23.93 mm,The eye model results in spherical aberration in good agreement with experimental data.