Abstract:The experimental data and theoretical analysis verify that harmful interference fringes in the holograms with large illumination angles are fringes of equal inclination caused by divergent reference beam.The experimental results show that such harmful interference fringes can be effectively eliminated either by using collimated reference beam in hologram recording or by attaching a piece of black paper on the surface of glass substrate of the recording plate.